Return-side pressureUndersized return ducts or grilles, restrictive filters, closed pathways, and poor return layout can create excessive negative pressure before the blower.
Supply-side pressureUndersized trunks, compressed flex, too many restrictive fittings, closed dampers, or downstream restrictions can consume available pressure after the blower.
Filter pressure dropA high-MERV filter is not automatically a problem; the question is its actual pressure drop at the system airflow and whether the filter rack has enough face area.
Coil and component dropsWhere the equipment arrangement allows it, component pressure measurements help separate a dirty/restrictive coil from a duct-system problem.
Blower setup + performance tableWe verify motor type, speed/airflow setting, and published blower data so we know what airflow the system should deliver at the measured pressure.
Room-by-room distributionIf total airflow is reasonable but a room is still uncomfortable, register airflow and duct layout can reveal a distribution problem instead of a whole-system restriction.